Precautions for offline cleaning of reverse osmosis membranes
Time:2023-08-01

Reverse osmosis membrane as a deep filtration means, its surface will inevitably residual colloids, microorganisms, impurity particles and insoluble salts on its surface precipitation. Therefore, once the reverse osmosis device is put into use, it eventually needs to be cleaned, but the length of the cleaning cycle is different. The cleaning of reverse osmosis membrane elements can be divided into two ways: online cleaning and offline cleaning. Online cleaning is a conventional cleaning method, mainly for the reverse osmosis system maintenance and maintenance. The biggest problem with online cleaning is that the concentration of the cleaning solution at the end of the cleaning direction will gradually decrease. When the reverse osmosis system runs for more than a certain period or the reverse osmosis membrane is seriously polluted, online cleaning is powerless, and it is necessary to clean the reverse osmosis membrane components offline.


1690851904148760.png


————————————————————————————————————————————————————————————————————————————————————


Conditions for off-line cleaning of reverse osmosis membrane:


1. When the single-stage pressure difference of the reverse osmosis system is more than 2 times of the single-stage pressure difference in the initial stage of the system operation.


2, reverse osmosis system water production decreased by more than 30%.


3, the weight of a single reverse osmosis membrane element exceeds the normal value of more than 3 kg.


4, the reverse osmosis system through online cleaning performance can not be restored.



1690851915102682.png

————————————————————————————————————————————————————————————————————————————————————


Features of Offline cleaning When cleaning online, the pertinency of the film in different positions is poor. Because a membrane shell is usually not a membrane element, so the pollution of these membrane elements is also different, when using the same concentration of cleaning liquid to clean the membrane of different pollution situations, it is inevitable that some membrane cleaning is excessive, and some membrane cleaning is insufficient, so the cleaning effect is poor, but also easy to form cross-contamination.


After the above reasons, I put forward the off-line cleaning method, its main characteristics are: use the spare membrane to replace the field use of reverse osmosis membrane, does not affect the user's normal production. The use of a special cleaning device for single reverse osmosis membrane cleaning, the device can be targeted to deal with different pollution conditions of the membrane, and can conveniently achieve reverse osmosis membrane positive and negative washing, with sufficient cleaning flow for a single membrane. During the cleaning process, the cleaning condition of the RO film can be monitored at any time, and the cleaning degree can be determined according to the actual situation. By analyzing the main components of the pollutants in the cleaning solution, the pollutants of the system are determined, and the corresponding system adjustment suggestions are put forward in order to extend the service life of the customer system.

1690851971127300.png

————————————————————————————————————————————————————————————————————————————————————


Off-line cleaning steps for reverse osmosis membranes


1. First, replace the membrane elements to be cleaned on the reverse osmosis system with spare membrane elements with excellent performance to ensure that the reverse osmosis system does not stop running and ensure the continuous stability of the entire production process.


2. Test the performance of reverse osmosis membrane components:


3. Understand the current operating status of the system before system cleaning; Collect the parameters and indexes of the reverse osmosis system and make the original records.


4. Judge the cleaning process according to the user's raw water full analysis report, performance test results and system information.


5. Identification of pollutants. First of all, according to the analysis results of 3.4, the preliminary judgment is made, and then the special equipment and appliances are further verified to determine the specific pollutant types.


6. According to the analysis results, determine the required cleaning formula and concentration.


7, in the reverse osmosis special cleaning equipment with the above cleaning agent combination treatment cleaning means for experimental cleaning, in order to choose the appropriate cleaning formula and cleaning procedures.


8, determine the cleaning method, and process all the above membrane elements.


9, the cleaned membrane elements into the test platform for testing and record, do not meet the requirements will be re-sent to the cleaning equipment for processing.



Weclome
Sichuan sidaneng Environmental Protection Technology Co., Ltd
MORE
Service Tel:
+86 189-8175-1540
Join Us
久久亚洲精品无码av| 久久人爽人人爽人人片AV| 国产伦精品一区二区三区免费迷| 成人奭片免费观看| 在车里被弄了h野战| 成人区精品人妻一区二区不卡| 老头在厨房添下面很舒服| 在图书馆里嗯啊好刺激h| 风流老熟女一区二区三区| 野外被三个男人躁一夜小说| 国产精品毛片av久久66| 久久久www成人免费毛片| 地铁上两个人一前一后攻击| 顶级私人家庭影院| 夜色暗涌时电视剧免费观看全集| 2023国精产品一二二线| sm鞭打高潮喷水抽搐调教玩弄| 中文字幕人妻无码专区| 国产免费av片无码永久免费| 国产亲妺妺乱的性视频播放| 警花新婚尝又大又粗| 亚洲国产成人精品无码区在线网站| 欧美性xxxxx极品少妇| 柳擎宇权力巅峰全文免费阅读正版| 色多多性虎精品无码av| 粗大的内捧猛烈进出| 97久久精品人人澡人人爽| 一受多攻同做h嗯啊巨肉| 女m被主人虐玩调教小说| 黑人狂躁中国人的a片| 亚洲日韩VA无码中文字幕| 好大好硬好深好爽想要寡妇| 国内女人喷潮完整视频| jlzz大全高潮多水老师| 久久精品国产亚洲av麻豆网站| 久久久久99精品成人片三人毛片| 老公一到晚上就日不停| 啊灬啊灬啊灬快灬高潮了视频网站| 被全班玩弄的小柔h| 国产在线精品一区二区三区不卡| 锕锕锕锕锕锕好大好湿|